NASA/CR-2000-210110 ICASE Report No. 2000-19 A Reduced Order Model of the Linearized Incompressible Navier-Stokes Equations for the Sensor/Actuator Placement Problem Brian G. Allan ICASE, Hampton, Virginia Institute for Computer Applications in Science and Engineering NASA Langley Research Center Hampton, VA Operated by Universities Space Research Association National Aeronautics and Space Administration Langley Research Center Prepared for Langley Research Center Hampton, Virginia 23681-2199 under Contract NAS1-97046 April 2000 A REDUCED ORDER MODEL OF THE LINEARIZED INCOMPRESSIBLE NAVIER-STOKES EQUATIONS FOR THE SENSOR/ACTUATOR PLACEMENT PROBLEM BRIAN G. ALLAN Abstract. A reduced order modeling approach of the Navier-Stokes equations is presented for the design of a distributed optimal feedback kernel. This approach is based on a Krylov subspace method where significant modes of the flow are captured in the model. This model is then used in an optimal feedback control design where sensing and actuation is performed on the entire flow field. This control design approach yields an optimal feedback kernel which provides insight into the placement of sensors and actuators in the flow field. As an evaluation of this approach, a two-dimensional shear layer and driven cavity flow are investigated. Key words. Navier-Stokes equations, feedback control, sensor/actuator placement, active flow control Subject classification. Applied Numerical Mathematics, Controls 1. Introduction. Experimental results using micro actuators and sensors have demonstrated that active flow control has the potential to increase the performance of high-lift wings, cavity noise, and other flow systems [13, 18, 5]. Placement of these micro actuators and sensors can have a dramatic effect on the performance of the flow control system. The location of the sensors and actuators is complicated by the distributed nature of the nonlinear flow equations and the dynamics of the closed-loop system. The goal of this investigation is to identify the spatial regions of the flow where sensing and actuation are favorable under feedback control. By assuming control and sensing everywhere in the flow field, a distributed optimal feedback kernel can be computed. Evaluation of this feedback kernel shows spatial regions of the flow field which are more significant, in terms of actuation and sensing, than other regions of the flow field [11]. By identifying these regions of the flow, the search space for the placement of sensors and actuators can be reduced. This methodology does not give exact locations for point actuators/sensors and should be considered as a prefilter to a point actuator/sensor location placement problem. Calculation of the optimal feedback gains requires a finite dimensional approximation to the infinite dimensional Riccati equations. The cost of computing this finite dimensional Riccati solution is order N3 where N is the number of states in the finite dimensional approximation to the dynamical system. Since the number of states needed to resolve a flow field can become very large, the cost of computing a solution to the Riccati equations can grow prohibitively expensive. However, this cost can be reduced by developing a reduced order model which contains significant dynam- ics of the flow system. To generate this reduced order model, the linearized incompressible Navier-Stokes equations are projected onto a Krylov subspace. This reduced order model is then incorporated into an optimal feedback control design. To evaluate this methodology a two-dimensional shear flow and a driven cavity flow problem are investigated. 2. Governing Equations. This section describes the equations governing the dynamics of a viscous flow in two-dimensions. In this investigation the incompressible Navier-Stokes equation are represented in vorticity stream function form. This form of the Navier-Stokes equation was chosen over the primitive variable form, i.e. velocity and pressure, because it has a reduced number of unknowns with no incompressibility condition. A disadvantage to the Institute for Computer Applications in Science and Engineering, Mail Stop 132C, NASA Langley Research Center, Hampton, VA 23681 (email: allan@icase.edu). This research was supported by the National Aeronautics and Space Administration under NASA Contract No. NAS1-97046 while the author was in residence at the Institute for Computer Applications in Science and Engineering (ICASE), NASA Langley Research Center, Hampton, VA 23681-2199. 1 vorticity stream function form is that the no-slip boundary conditions produce two boundary conditions on the stream function and none for vorticity [16]. 2.1. Two-Dimensional Navier-Stokes Equations. This investigation considers a two-dimensional square do- main D with a boundary D. The governing equations are the incompressible Navier-Stokes equations. These equations can be expressed in a vorticity stream function form. This form is achieved by taking the curl of the nondimensional momentum equation and substituting the definition of vorticity and stream function. The vorticity stream function form of the incompressible Navier-Stokes equations is then expressed as 1 u 2 in D t Re (2.1) 2 in D u ub on D where , , and u are the dimensionless scalar vorticity, stream function, and velocity vector respectively. Note that the velocity at the boundary must satisfy a compatibility condition which follows from the integration of the continuity equation over the domain D. Integrating the continuity equation over D, applying the divergence theorem, and using the velocity boundary condition, results in Z I (2.2) u ub n 0 D D where n is the unit vector normal to D [16]. The scalar vorticity field is the z-component of the vorticity vector u which is given by (2.3) ez u where the velocity vector u x t u v and ez is the unit vector normal to the xy plane. The stream function is defined such that (2.4) u v y x This definition of the stream function produces a velocity field which exactly satisfies the incompressibility condition u 0 for two-dimensional flows. The relation between the stream function and velocity vector can also be written in the compact form u ez. 2.2. Linearized Navier-Stokes Equations. The optimal feedback control design in this investigation is base on linear quadratic regulator (LQR) theory. Since the LQR control design is based on classical linear dynamic system theory, the nonlinear governing equations in Eq. (2.1) can not be used for the feedback control design. Therefore the equations in Eq. (2.1) are linearized about a desired base flow state where it is assumed that the flow is stabilized by the controller resulting in small perturbations about the base flow. These linearized Navier-Stokes equations describe the linear evolution of small perturbations about a given base flow field. It is desired that this base flow field be a steady state solution to the nonlinear governing equations. By making the base flow a steady state solution to the nonlinear equations, the time derivative of the base flow will drop out when the equations are linearized. This perturbation of the flow variables about some base flow state can be expressed as x t x x t (2.5) x t x x t u x t U x u x t 2 where the flow states , , and u satisfy equations in Eq. (2.1) and is some 'small' parameter. The perturbed states are represented by the variables , , and u and the base flow by , , and U U V . Here the base flow states are assumed to be steady state solutions and are not function of time. Substituting Eq. (2.5) into Eq. (2.1) and considering the terms which are of O 0 results in the equations, 1 0 U 2 in D Re (2.6) 2 in D U Ub on D These equations are the nonlinear steady state incompressible viscous flow equations. The desired flow state which is to be stabilized by the optimal feedback controller must satisfy the equations in Eq. (2.6). Considering now only the terms which are of O gives the equations, 1 U u 2 in D t Re (2.7) 2 in D u ub on D These equations describe the linear evolution of the perturbed flow state about the base flow state. The nonlinear term u is of O 2 and is dropped from above equations. The equations in Eq. (2.7) can be rewritten in the following conservative form, 1 U u 2 in D t Re (2.8) 2 in D u ub on D where the fact that the base flow velocity and the perturbed flow velocity satisfy the continuity equations U 0 and u 0 has been used. 2.3. Boundary Conditions. The physical boundary conditions on the velocity u at a wall result in two boundary conditions on the stream function . These two boundary conditions are derived by separating the normal and tangen- tial components of the velocity u at the boundary. Quartapelle (1993) shows that the boundary condition u D ub j results in the two boundary conditions (2.9a) D a j ææ (2.9b) b n æ æ D where a s t R s n ub t d and b ub. The variable s is a coordinate along the boundary D and s1 is s1 any fixed point along the boundary. The vector is a unit vector tangential to the boundary. For the flows considered in this investigation, the variable a s t 0. The two boundary conditions used in this investigation are periodic and no-slip nonporous walls. On the no-slip walls the Dirichlet boundary condition in Eq. (2.9a) was used to solve the Poisson equation for the stream function. The Neuman boundary condition Eq. (2.9b) for the stream function was used to solve the vorticity transport equation by deriving a Dirichlet boundary condition for vorticity. 3 3. Control Problem. The classical theory of control systems was developed for systems governed by finite dimensional ordinary differential equations (ODE), also known as lumped parameter systems. In this investigation the governing equations for fluid dynamics are partial differential equations (PDE) where the state of the system lies in some infinite dimensional function space. A system of this type is also known as a distributed parameter system where the states and control inputs are distributed spatially [10]. This section describes the LQR feedback control problem for the infinite dimensional system and its finite dimensional approximation. 3.1. Infinite Dimensional Problem. The distributed control applied to the flow takes the form of a spatially distributed body force f x t . The torque generated by the body force, normal to the xy plane, is given by g f ez. This distributed control torque g x t appears on the right-hand side of the linearized vorticity transport equation. 1 N N L g in D t U u Re (3.1) L in D æ æ D a b on D æ j n æ D These PDEs are now written in an abstract form which is conducive to the optimal feedback control design. Treating this distributed parameter system as an evolution ODE, Eq. (3.1) can be written as A Bg (3.2) x 0 0 where d t dt and A and B are infinite dimensional operators. The operator B for the system given in Eq. (3.1) is just the identity but is included for completeness. Given a flow field , the action of the operator A on is 1 (3.3) A U u 2 Re where the velocity u is an explicit function of the stream function , which is an implicit function of vorticity . The control input g is computed by using the state x t in the following way Z (3.4) g x t K x t d D where K x is the distributed feedback kernel. Therefore the control input g, at a position x, is given by an integral over the entire domain of the distributed gain K multiplied by the current vorticity field. The goal of this control design is to find a feedback kernel K which produced an optimal control input gopt. In order to define what optimal means, consider the following quadratic equation Z (3.5) J 0 g t Q t g t R g t dt ëh i h ië 0 where Q x and R x are weighting functions and the notation represents an inner product over the domain D. é é The term optimal is now defined as the control input which minimizes the quadratic cost function J. By minimizing J, the perturbations in the vorticity from the desired state are minimize and the needed control input g is also minimized. The LQR problem for the infinite dimensional system is stated as (3.6) min J x 0 g x t g x t 4 subject to the system in Eq. (3.2). The optimal control input gopt x t which minimizes Eq. (3.6) is given by Z (3.7) g 1 opt x t R B t d D where B is the adjoint of B and is the nonnegative self-adjoint solution to the steady state, infinite dimensional, algebraic Riccati equation (ARE) (3.8) A 1 A BR B Q 0 A solution exists for Eq. (3.8) if the pair A B is stabilizable and the pair A C is detectable [4]. These two conditions are satisfied since actuation and sensing are performed everywhere in the flow field. From Eq. (3.7) it can be seen that the optimal feedback kernel Kopt is given by (3.9) K 1 opt R B 3.2. Finite Dimensional Approximation. A finite dimensional approximation to the infinite dimensional feed- back kernel K is made using a finite difference method. In this approximation it is desired that the feedback kernel KN K, in an appropriate sense, as N . The computational issues associated with this problem have been addressed by Banks et al. [2] and Gibson [8]. The finite dimensional approximation to Eq. (3.5) is expressed as N AN N BgN (3.10) N 0 N 0 where N is a vector containing the spatially discrete values of the vorticity field and B is the identity matrix. The matrix B has been included in this investigation for completeness. The approximation to the quadratic cost function in Eq. (3.2) becomes Z (3.11) JN N gN æ N t QN N t æ ægN t RNgN t æ dt 0 0 where QN and RN are now matrices which weight the state vector N and the control input gN respectively. The finite dimensional control problem is stated as (3.12) min JN N gN 0 gN subject to the governing equations in Eq. (3.10). The optimal control input which minimizes Eq. (3.12) is given by (3.13) gN 1 opt t RN BN N N t where N is the solution to the finite dimensional ARE (3.14) AN 1 N NAN NBN RN BN N QN 0 As in the infinite dimensional case, a solution N exists for Eq. (3.14) if the pair AN BN is stabilizable and the pair AN CN is detectable [4]. This is easily satisfied since actuation and sensing are performed everywhere in the flow field. Equation Eq. (3.13) shows that the finite dimensional approximation to the optimal feedback gain Kopt is KN 1 opt RN BN N (3.15) Note that the finite dimensional approximation KN to the infinite dimensional feedback control K is dependent on the approximation to the ARE solution N and the adjoint BN . In this study, the BN matrix is IN N which means that the approximation KN is primarily dependent on the approximation N. 5 4. Reduced Order Model. The computational cost of solving Eq. (3.14) is on the order of N3 floating-point operations (flops), where N is the number of states. For two dimensional flows the number of flow states, for a computational simulation, can range anywhere from 104 to 105. For a simple two dimensional flow problem, say N 104, the cost would be on the order of 1012 flops. For a larger two dimensional flow problem, say N 105, the computational cost would increase by a factor of 1000, to 1015 flops. For three dimensional flows the number of states can range from 105 to 106. Thus, the cost of solving the ARE can grow prohibitively expensive, even for two dimensional flow problems. The computational cost can be reduced significantly by using a Chandrasekhar system approach [3]. The only draw back to the Chandrasekhar system is that the number of inputs must be much smaller than the number of states in order to significantly reduce the cost of solving the Riccati equation. Since the number of inputs for this problem are equal to the number of states, a different approach needs to be taken. Another way to reduce the cost, and the approach taken here, is to develop a reduced order model of the system given in Eq. (3.10). This reduced order model has a smaller number of states which reduces the cost of solving the Riccati equation in the LQR control design. Since the goal is to approximate the infinite dimensional LQR feedback gain, Kopt, a reduced order model which gives a good approximation should be chosen. It would also be desirable for the approximation to the infinite dimensional gain to converge in some reasonable way as the number of states in the reduced model increase. 4.1. Krylov Space Method. Most model reduction methods for feedback control systems use a Hankel-norm approach. This approach calculates Hankel singular values based on the controllability and observability of a given system. The advantage of this approach is that the H norm of the modeling error is bounded by the sum of the Hankel singular values not retained in the reduced order model. The draw back it that the cost of this approach is of order N3. In this study a Krylov based method is used to project Eq. (3.10) onto a reduced Krylov subspace which includes the leading modes of the larger system. This approach is significantly cheaper than the Hankel-norm approach but does not take into account the controllability and observability of the closed-loop system. It can be argued, that since actuation and sensing is performed everywhere in the flow field, that the leading modes of the homogeneous system are the dominant modes for the closed-loop system. If the matrix BN had some structure other than identity and sensing was not performed everywhere, then the leading modes of the homogeneous system are not necessarily the most dominant modes (modes with the largest real part) for the closed-loop system. Consider the homogeneous solution to Eq. (3.10), (4.1) N t T t N 0 where T t eANt is a C0-semigroup. Equation (4.1) can also be written as, N k t t T k t t N 0 T t T k t N 0 (4.2) T t N k t k 1 T t k where k N k t and the superscripts N have been dropped for convenience. Using a Krylov method, the action of the semigroup operator T t can be approximated by a reduced Krylov subspace. A kth-dimensional Krylov subspace, given an operator T t and a vector v, is defined as (4.3) K 1 k T v span v Tv T2v Tk v f g 6 This Krylov subspace is generated using the ARPACK software package which uses an Arnoldi/Lanczos scheme with implicit restarts [19]. The orthonormal basis for the Krylov subspace is generated by following the Arnoldi Process [1]. vj wj wj jj jj (4.4) k wj 1 Twj vm vm Tvj m 1 The vectors vj for j 1 2 k are computed using a given starting vector w1. The resulting N K vector V v1 v2 vk is known as a Ritz Vector where V K k T w1 . Note that the generation of the Krylov subspace only requires the action of T on a given vector and not the explicit matrix T. As shown in Eq. (4.2) the action of T on a given vector is just the advancement of the vector, or in this case the vorticity field, by one time step t. Equation (4.4) can be restated in the standard matrix form of the Arnoldi decomposition as (4.5) TV V H wk 1eT k where wk 1eTk is a remainder term. The matrix H is a K K upper Hessenberg matrix. The operator VVT is a N N projection operator onto the Krylov subspace and VTV is the K K identity matrix. The action of the semigroup operator T can be approximated by projecting it onto a Krylov subspace T VVT TVVT V HVT (4.6) where H VT TV for small wk 1eT k . Diagonalizing the matrix H yields (4.7) H E E 1 where is a diagonal matrix of eigenvalues and E is a matrix whose columns are the corresponding eigenvectors. The Krylov subspace is generated by using implicit restarts which keep the leading eigenvalues of the T semigroup operator. Using the definition of T t eA t and Eq. (4.6) an approximation to the operator A results in T t eA t V HVT (4.8) V E E 1 VT Solving for A produces log A VE E 1 VT t (4.9) A VHrVT where H 1 r E log E t. 4.2. Control Problem. Projection of the Nth dimensional system in Eq. (3.10) onto a kth dimensional Krylov subspace results in the reduced system z Hrz BrgN (4.10) z 0 z0 where Br VT and the aggregated state vector z is defined as z VT N (4.11) 7 Thus, the state vector N has been approximated by another state vector z, constrained to stay in the Krylov subspace given by the basis V. The vorticity state vector is then approximated as Vz. The system in Eq. (4.10) is now used to compute an approximation to the the desired optimal feedback gain KN given in Eq. (3.13). Using the Krylov subspace V the cost function in Eq. (3.11) results in Z (4.12) J z æ æ 0 gN z t Qrz t gN t RrgN t dt h i 0 where Rr RN and Qr VT QNV. The control problem defined in Eq. (3.12) for the reduced system becomes (4.13) minJ z0 gN gN subject to the governing equations in Eq. (4.10). The optimal control input for this problem is (4.14) gN 1 opt t R t r B r rz where the k k matrix, r, is the solution to the finite dimensional ARE (4.15) H 1 r r rHr rBrR Qr 0 r B r r Using Eq. (4.11) and Eq. (4.13), the approximation to the desired feedback gain KN becomes KN R 1 r V rV T (4.16) where the adjoint B r V. 5. Numerical Method. The calculation of T t on a given vector is achieved by computing a time accurate solution to the linearized Navier-Stokes equations described in Eq. (2.8). A solution to Eq. (2.8) is computed using a semi-implicit finite difference scheme. This scheme approximates the spatial derivatives using a second-order central difference method for the viscous term and a third-order upwind scheme for the convection terms. These equations are then solved using a multigrid acceleration method with Gauss-Seidel relaxation. 5.1. Time Discretization. The governing equations in Eq. (2.8) are discretized in time using an explicit up- winding scheme on the convection terms and a implicit Crank-Nicolson scheme on the diffusive term. This scheme is locally second-order accurate in space and first-order in time. The discretization of Eq. (2.8) has the form n 1 i j n 1 i j 1 h un h nU 2h n n t i j i j i j i j 2Re (5.1) 2h nij n i j where nij ih jh n t . The operators h, and 2h are discrete approximations to the operators and 2, respec- tively. The discretized vorticity transport equations in Eq. (5.1) can now be expressed as t 1 (5.2) I 2h n 1 n h un i j h nU i j 2h n 2Re i j i j i j 2Re The nonlinear Navier-Stokes equations in Eq. (2.1) are similarly discretized by replacing with n and U with un in the equation above. The steady state solution to the nonlinear equations in Eq. (2.1) are used in the linearized Navier-Stokes equation for the base flow field. The discretized equation in Eq. (5.2) can be expressed in the form (5.3) M n 1 b 8 where b is the right hand side of Eq. (5.2) and M the discrete operator I t 2Re 2h . Since M is a large and sparse matrix, the solution for n 1 favors an iterative method. To accelerate the iterative method, a multigrid routine which uses Gauss-Seidel relaxation is used. Likewise the solution to the Poisson equation in Eq. (5.1) is solved using an iterative method with multigrid acceleration. 5.2. Spatial Discretization. The Laplacian operator 2 is discretized using a standard second-order central dif- ference scheme and has the form n 2 n n n 2 n n (5.4) 2h n i 1 j i j i 1 j i j 1 i j i j 1 i j x2 y2 The first order derivatives in the linear convection terms are evaluated using a four-point upwind scheme. The x derivative component for the term h un i j, for u 0, is approximated by the upwind scheme u i j u 3 u 3 u u 2 u u i 1 j i j i 1 j i 2 j i 1 j i 1 j (5.5) q O x2 x 3 x 2 x where the parameter q controls degree of modification to the central difference term [6]. If q 0 5 then the scheme in Eq. (5.5) becomes an upwind scheme of O x3 . If q 0 then the scheme is reduced to a second-order central difference scheme. The central difference approximation for the linear convection term has good accuracy but will produce oscillations when the mesh Peclet number ( u dx Re) becomes greater than 2. The upwind scheme will reduce these oscillations for 2 but at a cost of reduced accuracy. This reduced accuracy is a result of artificial é diffusivity added by the upwind scheme. Therefore, a switch is used which sets q 0 when i j 2 and q 0 5 when é i j 2. This switch results in a scheme which has better accuracy at low mesh Peclet numbers than a straight upwind scheme, yet retains the advantages of an upwind scheme for large Mesh Peclet numbers. 5.3. Boundary Conditions. The boundary condition for the no-slip walls are computed using Jensen's formula- tion [9] attributed to Jensen by Roache [17]. This formulation, also known as Briley's formulation and was used by Pearson [14] and Ghia et al. [7]. Jensen's formulation computes a boundary value for the vorticity by taking a Taylor series expansion of the stream function normal to the wall. Jensen's formula is given by 7 8 3u 0 j 1 j 2 j 0 j 0 j O h2 (5.6) 2h2 h This boundary condition is claimed by [9, 17, 14, 7] to be O h2 for the vorticity at the boundary. It has been shown in [20] that this formulation can be thought of as an O h3 approximation to the Neuman boundary condition on the stream function in Eq. (2.9b) rather than a O h2 boundary condition for vorticity. If Eq. (5.6) is rewritten as h 7 8 0 j 1 j 2 j u O h3 (5.7) 3 0 j 0 j 6h then the limh 0 recovers the equation n 0 j u0 j. This is consistent with Eq. (2.9b), which is the equation j being modeled. Therefore the condition on the vorticity at the boundary can be thought of as an O h3 approximation to Eq. (2.9b) instead of an O h2 boundary condition for vorticity. Spotz used Jensen's formula using a compact 4th order method and showed that this formula resulted in an O h3 approximation. 5.4. Driven Cavity Problem. A numerical simulation of the driven cavity problem, using the full nonlinear Navier-Stokes equations in Eq. (2.1), is used to give a measure of validation for the proposed numerical method. The driven cavity problem is a typical two-dimensional model problem that is used to evaluate and compare numerical methods for incompressible viscous flows. Most notable are the steady state results published by Ghia et al. [7]. 9 UTop = 1 1 Solid Wall Boundary Conditions y x y=0 x=0 1 FIG. 5.1. Driven cavity problem 1 1 0.9 0.9 2 -1 0 -0.0001 2 0.8 0.8 1 -3 3 0.7 0.7 4 0.6 -0.1175 0.6 y 0.5 -0.11 y 0.5 -2 0.4 -0.09 0.4 0.3 0.3 4 -0.05 0.2 0.2 -0.01 3 0.0015 1 0.1 0.1 2 0.0001 0.001 0 0 3 2 0 0 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 x x FIG. 5.2. Stream lines of the driven cavity problem at steady FIG. 5.3. A contour plot of the steady state vorticity field for state for Re=1000. the driven cavity problem at Re=1000. The driven cavity problem, shown in Fig. 5.1, has a top wall which moves at a nondimensional velocity of UTop 1. The moving wall induces the flow as a result of the viscous forces generated at the moving wall. The steady state solution is then computed on a uniform grid which has 129 grid points in both the x and y directions. A steady state flow field is found by simply marching the impulsively started cavity in time, until a satisfactory steady state solution is achieved. Its interesting to note that this problem has two singularities at the top two corners where the top moving wall meets the two stationary side walls. The impact from these singularities are considered to be small since the grid is relatively fine. Figure 5.2 and 5.3 show the stream lines and vorticity contours for the steady state solution at Re 1000. The stream lines in Fig. 5.2 show two recirculation zones at the bottom corners of the cavity. The size and location of these recirculation zones compare very well the numerical results given by Ghia et al. [7]. The minimum stream function was computed to be min 0 117985 and compared very well to the minimum stream function, min 0 117929, computed by Ghia. The location of the center of the main vortex is computed to be at x 0 5312 0 5625 as compared to x 0 5313 0 5625 reported by Ghia. The contour plot of the vorticity field in Fig. 5.3 also compares 10 0.2 1 Present Re=100 Present Ghia Ghia 0 0.5 v(x,y=0.5) 0 -0.2 Re=100 u(x=0.5,y) -0.5 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 1 0.2 Re=400 0 0.5 -0.2 v(x,y=0.5) 0 -0.4 Re=400 u(x=0.5,y) -0.5 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 0.4 1 Re=1000 0.2 0.5 0 -0.2 v(x,y=0.5) 0 -0.4 Re=1000 u(x=0.5,y) -0.5 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 0.5 1 Re=3200 0.5 0 v(x,y=0.5) 0 Re=3200 u(x=0.5,y) -0.5 -0.5 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 x y FIG. 5.4. A comparison of the horizontal velocity profile, v, FIG. 5.5. A comparison of the vertical velocity profile, u, at the at the centerline of the cavity, y 0 5, with the profiles reported by centerline of the cavity, x 0 5 with the profiles reported by Ghia et Ghia et al. [7] at Re 100 400 1000 3200. al. [7] at Re 100 400 1000 3200. very well with the results from Ghia. Figure 5.4 shows the horizontal velocity profiles, v, at y 0 5 for Re 100 400 1000 and 3200. These velocity profiles are compared to the velocity profiles reported by Ghia et al. [7]. Likewise the vertical velocity profiles for u at x 0 5 are shown in Fig. 5.5 and then compared to the numerical data given by Ghia. These two figures show good agreement between the current results and the data from the Ghia paper. Note that a 129 129 grid was used for all the Reynolds number cases except for the Re 3200 case where a 257 257 grid was used as was done by Ghia. Based on these results a measure of validation has been shown for the proposed numerical method for the calculation of steady state flows. 6. Results. Application of the distributed feedback control design is now applied to an unstable shear layer problem and a stable driven cavity problem. The computed eigenvalues and eigenvectors for the bounded shear layer flow will be compared to eigenvalues and eigenvectors from an Orr-Sommerfeld analysis. This comparison will provide a measure of validation for the reduced order model. 6.1. Shear Flow Problem. The method described above is now applied to a two-dimensional bounded shear layer problem as shown in Fig. 6.1. In this problem there are two layers of parallel fluid traveling in opposite directions. At the intersection of these two flows is a shear layer which has a hyperbolic tangent velocity profile. The large velocity gradient in the shear layer results in a large concentration of vorticity. This type of flow pattern is inviscidly unstable to small disturbances. The base flow field for this problem is described by the equations 11 UTop = 1 1 U(y)=tanh(y/b) Periodic Boundary Conditions y x y=-1 x=-1 1 UBottom = -1 FIG. 6.1. The velocity profile in the y direction for the shear layer problem. U x y U y 0 U y b 0 0 tanh ë ë ë ë (6.1) 1 x 1 1 y 1 sech2 y b x y b where b 1 30, Re 100 and the flow is periodic in the x direction. The Reynolds number for the shear layer problem is typically defined using the characteristic length b, which determines the width of the shear layer. The Reynolds number for the shear layer is defined as U (6.2) Re 0b where U0 is the nondimensional characteristic velocity and the kinematic viscosity of the fluid. The U y profile is shown in Fig. 6.1 where the boundaries moving walls with a no-slip boundary condition. The velocity profile for this problem represents an exact solution to the steady state inviscid flow equations. However it does not exactly satisfy the steady state equations for the incompressible viscous flow. The unsteadiness, in this base flow, is due to the viscous diffusion term which wants to diffuse the high concentration of vorticity in the shear layer. This causes the vorticity layer to spread out and diffuse away from the center region. In practice this viscous diffusion effect is overlooked in the formulation of the linear stability problems. [15] 6.1.1. Reduced Order Model. Using the shear layer base flow field given in Eq. (6.1), a Krylov basis vector V of dimension K 201 was constructed to form the reduced order model in Eq. (4.10). These vectors were found using the ARPACK software package where the top 201 eigenvectors with the largest real part were computed. This program starts by generating a large Krylov subspace of 600 Ritz vectors. It then performs an implicit restart which removes unwanted Ritz vectors and then generates new Ritz vectors, replacing the discarded vectors. This process is repeated until the desired number of leading eigenvectors has converged. For this problem, 2735 T operations (time steps) were computed by the flow solver. The finite difference approximation was made using 64 grid points in the streamwise direction and 128 grid points in the cross stream direction. Figure 6.2 shows the convergence of the ARPACK routine where an implicit restart was performed at the start of a new iteration. The convergence rate is dependent on the number of desired eigenvectors, the size of the Krylov subspace chosen, and the size of the time step. The top 201 eigenvalues, with the largest real parts, are shown in Fig. 6.3. These eigenvalues are compared to the eigenvalues computed from an Orr-Sommerfeld stability analysis using the spectral method presented by Orszag[12]. The numerical method used by Orszag was derived for the stability of plane Poiseuille flow which was then modified for the shear layer problem. The comparison between the eigenvalues shows how the Krylov method was able to com- 12 200 150 100 50 Number of Converged Krylov Vectors 00 2 4 6 8 Iteration Number FIG. 6.2. The convergence history of the Krylov vectors using the ARPACK software package. The Krylov subspace had 600 vectors and was looking for the top 201 eigenvectors with the largest real parts. pute the eigenvalues of the shear layer problem reasonably well. From this figure it can be seen, that the eigenvalues start to degrade as the imaginary parts become larger and as the real parts of the eigenvalues become increasingly negative. The reduced accuracy of the eigenvalues in these areas show the limitations of the finite difference approxi- mation and the computation of the eigenvalues using the Krylov time stepping method. As the imaginary and negative real parts of the eigenvalues increase, so do the spatial oscillations of the eigenvectors. Therefore the spatial resolution of the finite difference method governs how many of the eigenvectors can be resolved accurately. For the shear layer problem, the number of modes that can be resolve are sufficient our investigation. A sample of the eigenvectors computed using the Krylov method and the Orr-Sommerfeld analysis are shown in Fig. 6.4. A Fast Fourier Transform (FFT) was taken of the eigenvectors, generated by the Krylov method. This FFT showed that the eigenvectors have one dominant wave number in the x direction. Therefore the eigenvectors can be expressed in the form V x y v y ei x (6.3) where Fig. 6.4 is showing the function v y for four different eigenvectors. Figure 6.4a shows the most unstable eigenvector for the shear flow problem. This mode has a wave number of 2 and shows the form of the instability of the shear layer. This eigenvector compares very well to the eigenvector computed using the Orr-Sommerfeld spectral analysis. This unstable mode is the easiest mode to capture using this Krylov method since it grows very fast. The other eigenvectors in Fig. 6.4b through d are stable modes. The eigenvectors shown in Fig. 6.4b and d both have wave numbers and the eigenvector in Fig. 6.4d a wave number of 2 . These modes compare very well with the corresponding eigenvector from the Orr-Sommerfeld analysis. This comparison shows a measure of validation in computing the leading eigenvectors and eigenvalues using the Krylov method. This comparison also shows that the eigenvalues start to degrade in accuracy for eigenvalues with increasing wave numbers and negative real parts. The accuracy of the eigenvalues and eigenvectors can be improved by increasing the spatial resolution and by using a numerical scheme of higher order. It was also seen that decreasing the time step could improve the accuracy of the eigenvalues up to some limit. Further reduction of the time step beyond this limit did not increase the accuracy of the eigenvalues. 6.1.2. LQR Control Design. The optimal feedback kernel for the reduced system was computed by minimizing the quadratic cost function in Eq. (4.12). The weights for the cost function in Eq. (3.11) were set to R I and Q I. 13 This resulted in the weights for Eq. (4.12) (6.4) Rr I Qr VT QV VTV I The ARE for the reduced system, given by Eq. (4.15), is then solved for r using the MATLAB software package. This reduced system results in an ARE solution with 201 states, which is large for typical ARE problems, but is significantly smaller than the 8192 states of the full system. Figure 6.5 shows the diagonal elements of the ARE solution r as a function of the mode number. The modes are the eigenvectors of the linearized flow equations and the eigenvalue i corresponds to the ith mode where Re i Re i 1 . This figure shows how the first six modes, which are unstable modes, result in the largest contribution to the feedback kernel KN and how the contribution decreases for the higher mode numbers. This figure basically shows the convergence of the feedback kernel with respect to the size of the reduced order system. Substituting r into Eq. (4.16) results in the approximation to the finite dimensional feedback kernel KN. Using the approximation to KN the optimal feedback control can be computed as (6.5) gNopt t KN N t where KN is a 8256 8256 matrix, gN 8256 1 column vector, and N a 1 8256 row vector. It can be opt a seen from Eq. (6.5) that the nth column of KN corresponds to the distributed control input g for a disturbance en. Similarly, the mth row of KN correspond to the distributed feedback gain for the control input at gm. To illustrate this idea Fig. 6.6 shows the distributed control gNopt given a unit disturbance at four different locations in the flow. Figure 6.6a shows the point disturbance on the bottom wall and shows a local positive control near the point distur- bance. Fig. 6.6b shows the disturbance just off the wall at y 0 75 and shows the localized nature of this feedback control. In Fig. 6.6c the disturbance is move closer to the shear layer. This figure shows the same type of localized feedback control around the disturbance as before but with a large control force. The disturbance near the shear layer also shows an interesting feedback control force which appears in the shear layer. The point disturbance is then moved to the center of the shear layer as is shown in Fig. 6.6d. This distributed feedback control shows a pattern which is similar to the unstable modes in the flow. This should be expected since the unstable modes were associated with the largest feedback gains computed in r. In an effort to quantify the spatial structure of the control effort a norm is defined in the following way N 1 2 (6.6) c 2 n KN m n m 1 where cn is the nth element of a vector defining the control effort and c c1 c2 cN . The idea is for cn to be a measure of the control effort in an L2 norm sense for a point disturbance located at en. Likewise the spatial structure of the feedback gain can be evaluated by defining the norm N 1 2 (6.7) f 2 m KN m n n 1 where f f1 f2 fN is a vector describing the measure of the feedback effort. The value of fm is an L2 norm of the distributed feedback gain for actuation at gm. Note that the feedback kernel is symmetric since the weight R and the matrix B are symmetric. Therefore the the vectors c and f, which describe the control effort and feedback effort, are equal. A plot of the control effort at a constant x value, for the shear flow problem, is shown in Fig. 6.7. This figure shows how the control effort, and consequently the feedback gain, is large in the shear region. This figure also shows that the shear region would be most favorable for actuation and sensing as might be expected. 14 6.2. Cavity Flow Problem. The second problem involved the design of a distributed feedback controller for a driven cavity problem. Unlike the shear layer, the base flow field for the driven cavity was stable and satisfies the finite difference approximation to the steady state flow equations. Since the flow is stable, the model will not contain any unstable modes as was seen in the shear layer problem. This means that the cavity problem will not have a small number of dominant modes in the reduced order model and feedback kernel as was seen in the shear layer problem. 6.2.1. Reduced Order Model. The base flow field for the cavity problem was the steady state flow field com- puted in section 5.4 for Re 1000. The vorticity for the base flow is shown in Fig. 5.3 and the stream function in Fig. 5.2. Using this base flow field, a Krylov basis vector V of dimension K 400 was constructed to form the reduced order model of the linearized flow equations. Figure 6.8 show the convergence of the top eigenvalues with the largest real parts. It took 50 implicit restarts and 15370 T operations (time steps) by the flow solver in order for the top 400 modes to converge. The distribution of the top eigenvalues is shown in Fig. 6.9. A sample of the eigenvectors with the largest real parts are shown in Fig. 6.10. This figure shows the real and imaginary parts of the eigenvectors. Notice that some of the eigenvectors are real and do not have any imaginary parts. 6.2.2. LQR Control Design. Using the reduced order system for the linearized cavity flow, the optimal feedback kernel is then computed using an LQR control design approach. As in the shear layer problem, the Riccati solution r to the ARE in Eq. (4.15) was computed which minimizes the cost function in Eq. (4.12). The weights for the cost function in Eq. (3.11) are uniform and set to R I and Q I which results in the weights Rr I and Qr I. Figure 6.11 shows the diagonal elements for r as a function of the mode number. This figure shows a similar decay rate for the diagonal elements of the Riccati solution r as compared to the shear flow problem. The feedback kernel KN can now be approximated by substituting the Riccati solution to the reduced system r into Eq. (4.16). This results in a 16641 16641 feedback kernel KN where the approximation to the optimal distributed control gNopt is given by (6.8) gNopt t KN N t Using this optimal feedback kernel, the distributed control for a point disturbance can be computed. Figure 6.12 shows the approximation to the distributed control given a point disturbance at four different locations in the cavity. A point disturbance on the bottom wall is shown in Fig 6.12a with the resulting distributed control force. Figures 6.12b through d show the point disturbance in the interior of the cavity away from the effects of the wall. The distributed feedback for these interior points show a smooth circular pattern around the disturbance. This figure also shows that the applied control force is a maximum at the point disturbance and then decays as it moves away from the disturbance location. It is interesting to see how the control force decays as it moves away from the location of the point disturbance. Figure 6.13a shows a mesh plot of the distributed control shown in Fig 6.12c and Fig 6.13b shows a plot of the distributed control for y 0 5. These figures illustrate how the control force decays from the point disturbance located at x y 0 5 0 5 . The distributed control effort and feedback gain for the cavity problem is shown as a mesh plot in Fig. 6.14 and as a contour plot in Fig. 6.15. These two figures show how the distributed control effort and feedback gain are concentrated in the center of the cavity. There are also some peaks near the center of the walls and one large peak where the flow induced from the top moving lid impinges on the right stationary wall. The figure also shows that the control effort is smaller at the corner of the cavity. Therefore sensing and actuation would be most favorable near the center of the cavity, near the center of the wall, and on the top part of the right wall. 7. Conclusion. This study has demonstrated how a Krylov subspace method can be used to derive a reduced order model of the linearized incompressible Navier-Stokes equations and applied to a two-dimensional shear flow 15 and driven cavity problem. By assuming sensing and actuation everywhere in the flow field an optimal feedback kernel can be found. This feedback kernel provides insight into the regions of the flow where the control effort is `large' and where the feedback gain is `large'. This information can be used to isolate the regions of the flow field where sensing and actuation are most favorable. This information also shows where one should be searching for the best place to put actuators and sensor. This knowledge has the potential to reduce the search areas of the flow field for the placement of actuators and sensors. In the shear layer case, the search area could be significantly reduced, where as the driven cavity problem only showed a slight reduction in the search area was achieved. The two-dimensional shear flow problem showed that sensing and actuation was most favorable in the shear layer as might be expected. The driven cavity problem showed that a region in the center and parts of the walls were the most favorable for the placement of sensors and actuators. It also showed that there was not a dominant region, as in the shear layer problem, and that the corners of the cavity and a region near the walls were unfavorable for the placement of sensors and actuators. The advantage of this approach is that a simple time stepping vorticity stream function code could be used to derive the linearized model of the incompressible Navier-Stokes equations. To improve on this approach, higher-order spatial discretizations should be used to improve the spatial accuracy of the higher frequency modes. The drawback to the time stepping approach used here is the convergence of the eigenvalues and eigenvectors. To solve this problem a shift invert approach described by Sorensen [19] can be used but this requires an explicit representation of the flow equations as oppose to the coupled vorticity stream function equations used here. 8. Acknowledgments. The author wishes to acknowledge the helpful discussions provided by Dr. Josip Lon- caric. REFERENCES [1] W. E. ARNOLDI, The principle of minimized iterations in the solution of the matrix eigenvalue problem, Quart. Appl. Math., 9 (1951), pp. 17­29. [2] H. T. BANKS AND R. H. FABIANO, Approximation issues for applications in optimal control and parameter estimation, Tech. Report TR97-11, CRSC, North Carolina State University, Raleigh, NC 27695-8205, 1997. [3] H. T. BANKS AND K. ITO, A numerical algorithm for optimal feedback gains in high dimensional lqr problems, Tech. Report 86-76, ICASE, Mail Stop 132C, NASA Langley Research Center, Hampton, VA 23681-2199, November 1986. [4] H. T. BANKS, R. C. SMITH, AND Y. WANG, Smart Material Structures: Modeling, Estimation, and Control, J. Wiley, Paris/Chichester, 1996. [5] L. N. CATTAFESTA, S. GARG, M. CHOUDHARI, AND F. LI, Active control of flow-induced cavity resonance, AIAA 97-1804, 1997. [6] C. A. J. FLETCHER, Computational Techniques for Fluid Dynamics, Volume I, Springer-Verlag, New York, 1991. [7] U. GHIA, K. N. GHIA, AND C. T. SHIN, High Re solutions for incompressible flow using Navier-Stokes equa- tions and a multi-grid method, Journal of Computational Physics, 48 (1982), pp. 387­411. [8] J. S. GIBSON, Linear-quadratic optimal control of hereditrary differential systems: Infinite dimensional Riccati equations and numerical approximations, SIAM J. Control and Optimization, 21 (1983), pp. 95­139. [9] V. G. JENSEN, Viscous flow around a sphere at low Reynolds number ( 40), Proceedings of the Royal Society of London. Series A, 249 (1959), pp. 346­366. 16 [10] J. L. LIONS, Optimal control of systems governed by partial differential equations, Springer-Verlag, New York, 1971. [11] J. LONCARIC, Sensor/actuator placement via optimal distributed control of exterior Stokes flow, in Proceedings, AFOSR Workshop on Optimal Design and Control, J. Borggaard, J. Burns, E. Cliff, and S. Schreck, eds., Boston, Oct. 1997, Birkhauser. [12] S. A. ORSZAG, Accurate solution of the Orr-Sommerfeld stability equation, Journal of Fluid Mechanics, 50 (1971), pp. 689­703. [13] L. G. PACK AND R. D. JOSLIN, Overview of active flow control at NASA Langley Research Center, in SPIE's 5th Annual International Symposium on Smart Structures and Materials, San Diego, CA, March 1998. [14] C. E. PEARSON, A computational method for viscous flow problems, Journal of Fluid Mechanics, 21 (1965), pp. 611­622. [15] C. PORIKIDIS, Introduction to Theoretical and Computational Fluid Dynamics, Oxford University Press, New York, 1997. [16] L. QUARTAPELLE, Numerical Solution of the Incompressible Navier-Stokes equations, Birkh¨auser Verlag, Boston, 1993. [17] P. J. ROACHE, Computational fluid dynamics, Hermosa Press, Albuquerque, NM, 1972. [18] A. SEIFERT, A. DARABI, AND I. WYGNANSKI, Delay of airfoil stall by periodic excitation, AIAA Journal of Aircraft, 33 (1996), pp. 691­699. [19] D. P. SORENSEN, Implicitly restarted arnoldi/lanczos methods for large scale eigenvalue calculations, Tech. Report 96-40, ICASE, Mail Stop 132C, NASA Langley Research Center, Hampton, VA 23681-2199, May 1996. [20] W. F. SPOTZ, Accuracy and performance of numerical wall boundary conditions for steady, 2d incompressible stream-function vorticity, Int. J. Numer. Meth. Fluids., 28 (1998), pp. 737­757. 17 30 Krylov (64 × 129) Orr-Sommerfeld 20 10 0 -10 -20 -30 -10 -8 -6 -4 -2 0 2 FIG. 6.3. A comparison of the 201 eigenvalues computed using the Krylov method using the two-dimensional finite difference numerical approximation, to the one-dimensional Orr-Sommerfeld analysis using a spectral method at Re 100. The eigenvalues for the Orr-Sommerfeld equations were computed using wave numbers, in the x direction, equal to 0 2 3 , and 4 . 1 Finite Difference 1 Chebychev 0 Real 0 Real =1.548 -1 =-0.3803-3.122i -1 -0.5 0 0.5 1 -1 -1 -0.5 0 0.5 1 0.2 2 0 0 Imaginary -2 Imaginary -1 -0.5 0 0.5 1 -0.2 -1 -0.5 0 0.5 1 (a) y (b) y 1 1 0 Real 0 Real =-0.5757-6.232i =-0.8586-3.106i -1 -1 -1 -0.5 0 0.5 1 -1 -0.5 0 0.5 1 0.2 0.2 0 0 Imaginary Imaginary -0.2 -0.2 -1 -0.5 0 0.5 1 -1 -0.5 0 0.5 1 (c) y (d) y FIG. 6.4. A comparison of eigenvectors computed using the Krylov method to a one-dimensional Orr-Sommerfeld analysis which is solved using a spectral method. 18 3 2.5 2 1.5 1 Diagonal term 0.5 00 50 100 150 200 Mode number FIG. 6.5. The value of the diagonal elements for r, the solution of the ARE for the reduced system. The first six modes are unstable and therefore produce large values in r solution. The other modes are all stable and the contribution of these modes to the feedback kernel decreases for the modes with increasing negative real parts. 1 1 0.8 0.8 0.6 0.6 0.4 0.4 0.2 0.2 y 0 y 0 -0.2 -0.2 -0.4 -0.4 -0.6 -0.6 -0.8 -0.8 -1 -1 -0.5 0 0.5 1 -0.5 0 0.5 1 (a) x (b) x 1 1 0.01 0.8 0.8 0.6 0.6 0.005 0.4 0.4 0.2 0.2 0 y 0 y 0 -0.2 -0.2 -0.005 -0.4 -0.4 -0.6 -0.6 -0.01 -0.8 -0.8 -1 -1 -0.5 0 0.5 1 -0.5 0 0.5 1 (c) x (d) x FIG. 6.6. This figure shows the spatial distribution of the applied control gN x for a unit disturbance which is shown by the black dot. In these four figures the unit disturbance is moved along the y axis from the wall to the center of the shear layer. 19 2x 10-3 1.5 1 Control Effort 0.5 0 -1 -0.5 0 0.5 1 y FIG. 6.7. A measure of the control effort and feedback gain. 400 300 200 100 Number of Converged Krylov Vectors 00 10 20 30 40 50 Iteration Number FIG. 6.8. The convergence history of the Krylov vectors using the ARPACK software package for the cavity problem. The Krylov subspace had 800 vectors and was looking for the top 400 eigenvectors with the largest real parts. 30 20 10 Im 0 -10 -20 -30 -8 -6 -4 -2 0 Re FIG. 6.9. Eigenvalues of the driven cavity problem for Re 1000. 20 =-0.0681+0.0000i =-0.1386+0.9872i Real Imag Real Imag (a) (b) =-0.1964+0.0000i =-0.2351-1.9914i Real Imag Real Imag (c) (d) =-0.2870+0.0000i =-0.3301-0.9310i Real Imag Real Imag (e) (f) =-0.3367-2.9876i =-0.5086+0.0000i Real Imag Real Imag (g) (h) =-0.5308-1.9463i =-0.5655-0.9456i Real Imag Real Imag (i) (j) FIG. 6.10. Real and imaginary parts of the top eigenvectors for the cavity problem. 21 =-0.5655+0.9456i =-0.5850-4.9597i Real Imag Real Imag (k) (l) =-0.6387-1.6238i =-0.6584-2.9347i Real Imag Real Imag (m) (n) =-0.6782-0.3169i =-0.7297-5.9365i Real Imag Real Imag (o) (p) =-0.8160-3.9110i =-0.8405-1.0665i Real Imag Real Imag (q) (r) =-0.8405+1.0665i =-0.8889-6.9079i Real Imag Real Imag (s) (t) 22 1 0.9 0.8 0.7 0.6 0.5 0.4 Diagonal Term 0.3 0.2 0.1 00 100 200 300 400 Mode Number FIG. 6.11. The value of the diagonal elements for r for the cavity problem. 1 1 0.9 0.9 0.8 0.8 0.7 0.7 0.6 0.6 y 0.5 y 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 (a) x (b) x 1 1 0.008 0.9 0.9 0.8 0.8 0.006 0.7 0.7 0.6 0.6 0.004 y 0.5 y 0.5 0.4 0.4 0.002 0.3 0.3 0.2 0.2 0.000 0.1 0.1 0 0 0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1 (c) x (d) x FIG. 6.12. This figure shows the spatial distribution of the applied control gN x for a unit disturbance which is shown by the black dot. In these four figures the unit disturbance is moved along the y axis from the wall to the center of the shear layer. 23 x 10-3 8 8 x 10-3 6 7 4 6 5 2 Control Force 4 0 3 Control Force -2 2 1 1 1 0.5 0.5 0 -1 y 0 0 0.2 0.4 0.6 0.8 1 (a) 0 x (b) x FIG. 6.13. These two figures show the distributed control force gN x for a unit disturbance located at the center of the cavity. A mesh plot showing the spatial distribution of the control force is shown in a and plot of gN x for y 0 5 is shown in b. 0.015 0.01 0.005 01 0.8 1 0.6 0.8 0.6 0.4 0.4 0.2 0.2 0 0 FIG. 6.14. A mesh plot showing the control and feedback effort for the forced cavity problem. 24 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 00 0.2 0.4 0.6 0.8 1 FIG. 6.15. A contour plot showing the control and feedback effort for the forced cavity problem. 25